35v 70000A DC Pulse Stainless steel electrolytic polishing power supply With PLC Control
GENRAL SEPCIFICATION
AC Input | voltage | 415V |
frequency | 50/60hz | |
phase | 3 phase | |
output | current | 0~7000a optional |
voltage | 0~35v adjustable | |
frequency | 40khz | |
effiencicy | ≥89% | |
voltage stability | ≤1% | |
current stability | ≤1% | |
Stabilization mode | Current stabilization/Voltage stabilization (Switchable easily) | |
adjustment range | Voltage/Current from 0-100% continuously adjustable within rated range | |
control part | cooling system | air cooling /water cooling/mixed water & air cooling |
control method | local panel control/remote control box/ PLC | |
Display contents | Voltage meter/Current meter/Working/Over temp/Error, etc.. | |
Protection method | Input over voltage/Under voltage/Over current/Output short/Over heating self protection etc. | |
use environment | Operating temperature | -20-50℃ |
Ambient temperature | 30-65℃ | |
Ambient humidity | ≤90% | |
Working loading | Full capacity operation, more than 1,000 meters above sea level, reduced load operation |
Rectifier: Three-phase 380V, rectified current, according to customer's workpiece size. Operating voltage 8-20v.
The principle of stainless steel electrolytic polishing:
The currently accepted theory is mainly the theory of stainless steel electrolytic polishing mucosa. This is: metal ions are separated from the workpiece and phosphoric acid forms a phosphate film adsorbed on the surface of the workpiece.This mucous membrane is predicted to be thinner and thicker at rest, because it is predicted that the high current density will quickly dissolve, the fluidity of the mucus membrane, the irregularities change, rough The surface gradually becomes smooth.
Advantages of stainless steel electrolytic polishing:
(1) The interior and exterior of the same color are flattened without gloss and mechanical polishing without rest.
⑵High production efficiency and low cost.
⑶ Increase the corrosion resistance of the surface, suitable for all stainless steel.
35v 70000A dc pulse metal electropolishing power supply with PLC control wavefrom
Cabinet: anodizing rectifier cabinet adopts magnetic cut links, reduce eddy current losses, and cabinet as a whole spray painting |
Structure: Reasonable structure design, isolated the inverter part and , rectification part , convenient to disassemble and maintenance |
Radiator: radiator capacity expanded 1.5 times,make sure better cooling effect |
switch control way: adopt full bridge phase shifting soft switch,reduct IGBT loss,save engergy |
Main transfadopts igbt anodizing rectifier amorphous core,increase transformer efficiency,reduct the transformer temperature rise,cut the rectifier weight,improve the power supply stability, reliability |
Core & Schottky diode: core capacity expanded 1.5 times schottky diode expands 4 times
|
Board : plating rectifier all control boards did anticorrosion treatment with imported three defense lacquer |
IGBT: hard anodizing rectifier IGBT capacity expanded 3 times,make the power supply more reliable |
Pre-Sales Service * Inquiry and consulting support within 12 hours. * Sample testing support. * View our Factory. |
After-Sales Service * Training how to instal the machine, training how to use the 35v 70000A dc pulse metal electropolishing power supply with PLC control * warranty :18 months * Engineers available to service machinery overseas. |
1,Placing 35v 70000A dc pulse metal electropolishing power supply with PLC control and keep the body stability; ensure good ventilation. |
2,Checking hard anodizing rectifier for sale out cover if loosing. |
3,Connecting shell to ground to prevent static electricity. |
4,Conecting the AC input wire |
5,Connecting the DC output copper bars |
6,Connecting the remote control box,if local control ,skip this step |
7,Turn on air switch, then the fan starts to rotate and the power indicator light. |
8,Clockwise rotation adjustment button, voltmeter degree increases, working indicate light lighting. |
9,Adjust knob to maximum, then the voltmeter should indicate the rated voltage, current meter indicates the load volume accordingly. |
10,Disconnect the air switch, turn off the power |